Bently Nevada 1900/65A-00-01-01-00-00 General Purpose Equipment Monitor with display
Bently Nevada 1900/65A-00-01-01-00-00 General Purpose Equipment Monitor with display
Brand:
Bently Nevada TSIItem NO.:
1900/65A-00-01-01-00Order(MOQ):
1Payment:
T/TProduct Origin:
USAShipping Port:
XIAMENLead Time:
IN STOCKWarranty:
1 Year
Bently Nevada 1900/65A-00-01-01-00-00 General Purpose Equipment Monitor
Description:
The 1900/65A General Purpose Equipment Monitor is a machinery vibration monitor designed to continuously monitor and protect equipment used in a variety of applications and industries. The monitor’s low cost makes it an ideal solution for general-purpose machines and processes that can benefit from continuous monitoring and protection.
Inputs
The 1900/65A provides four transducer inputs and four temperature inputs. Software can configure each transducer input to support 2- and 3-wire accelerometers, velocity sensors or proximity sensors. Each temperature input supports Type E, J, K, and T thermocouples, and 2- or 3-wire RTDs.
Outputs
The 1900/65A provides six relay outputs, four 4-20 mA recorder outputs, and a dedicated buffered output. The user can use the 1900 Configuration software to configure the relay contacts to open or close according to the OK, Alert and Danger statuses of any channel or combination of channels, and to provide data from any variable from any channel on any recorder output. The dedicated buffer output can provide the signal for each transducer input.
A Modbus Gateway option allows the monitor to provide static variables, statuses, event list, time and date information directly to any Modbus client, including Distributed Control Systems (DCSs), Supervisory Control and Data Acquisition (SCADA) systems, Programmable Logic Controllers (PLCs), or System 1 software. The monitor uses an internal counter and a Modbus client/master time reference to generate time and date information. Users can upgrade monitors without the Modbus Gateway by ordering the 1900/01 Communications Upgrade (see the Ordering Information section). The 1900/65A supports Modbus communications via Ethernet and a software-configurable RS232/485 serial port.
Configuration
The user defines monitor operation and the Modbus Gateway register map by using software running on a laptop or PC to create a configuration file and download the file to the monitor through the built-in Ethernet connection. The 1900/65A permanently stores configuration information in non-volatile memory, and can upload this information to the PC for changes.
Display Module
The 1900/65A supports an optional display/keypad to view channel information or make minor configuration changes. This allows the 1900/65A to operate as a stand-alone package. If desired, the user can mount the display up to 75 metres (250 feet) from the Monitor Module.
Ordering Information:
1900/65A-AA-BB-CC-DD-EE
A: Power Option |
|
00 |
18 to 36 Vdc |
01 |
110 to 220 Vac @ 50 to 60 Hz (external supply) |
B: Display Option |
|
00 |
No display |
01 |
Attached display (no cable) |
02 |
Display with 10’ PVC cable |
03 |
Display with 10’ unassembled PVC cable |
04 |
Display with 10’ TEF cable |
05 |
Display with 10’ unassembled TEF cable |
C: Mounting Option |
|
00 |
None |
01 |
DIN rail mount |
01 |
Bulkhead Mount |
03 |
Fiberglass NEMA 4X/IP66 WP housing with window in door |
04 |
1900/55 replacement kit |
07 |
ProTIM Housing, Wiring and Mounting Hardware |
D: Approvals Options |
|
00 |
None |
01 |
Multiple approvals |
E: Communications Option |
|
00 |
None |
01 |
Modbus communicationsw |